ESVAÀÇ F75-2830 ÆÄÀ̹ö ä³Î (FC) Æ÷Æ® ¹× iSCSI Æ÷Æ®¸¦ ¸ðµÎ °®Ãá ÇÏÀ̺긮µå SAN ½ºÅ丮Áö ½Ã½ºÅÛÀÔ´Ï´Ù. °í¼º´É µå¶óÀ̺ê´Â ¸¸Á·½º·´°Ô Æ®·£Àè¼Ç ¿öÅ©·Îµå¸¦ ¿ä±¸, ó¸® ÇÒ ¼ö ÀÖ½À´Ï´Ù.½ºÅ丮Áö Ç®¿¡ 12 ESVA ½Ã½ºÅÛ±îÁö ÅëÇÕÇÔÀ¸·Î½á, ÃÖ´ë ¿ë·®Àº 4800 µå¶óÀ̺ê·Î È®Àå ÇÒ ¼öÀÖ½À´Ï´Ù. ¶Ç iSCSI Æ÷Æ®´Â Àú·ÅÇÑ ºñ¿ëÀ¸·Î ¿ø°Ý º¹Á¦¸¦ ÇÒ ¼ö ÀÖ½À´Ï´Ù.

±â´É

ÀåÁ¡

Large storage capacities

Up to 4800 HDD, Ideal for applications with extreme capacity requirements, such as HPC and data archiving

Storage virtualization

Eliminate physical boundaries of storage consolidation

Thin provisioning

Ensure the most efficient allocation of pooled capacity

Automated storage tiering

  • Easily meet different service level requirements with up to four tiers distinguished by drive types and RAID levels
  • Achieve optimized data distribution in storage pool with automated data migration
  • Efficiently use SSDs to optimize performance by up to 150% at no additional costs compared to a non-tiered configuration
  • Distributed load balancing

    Make performance grow linearly by adding subsystems to the virtualized foundation

    Prioritized volume accessibility

    Ensure applications to achieve their ideal service levels

    Data protection:
  • Snapshot
  • Volume copy/Volume mirror
  • Sync and async remote replication
  • Support the highest data availability and quick service restart after storage accidents

    Green design:
  • High-efficiency power supplies
  • Intelligent multi-level drive spin-down technology
  • 80 PLUS-certified power supplies delivering more than 80% energy efficiency
  • In spin-down state, drives can save up to 60% of energy consumption
  • Eight 8Gb/s Fibre Channel host ports

  • Best-of-class throughput and IOPS, ideal fit for IO-intensive and bandwidth-demanding applications
  • Backward compatible with 4Gb/s or 2Gb/s speeds, protecting current infrastructure investment
  • Four 1Gb/s iSCSI ports

  • Achieve highly cost-effective remote replication through iSCSI ports
  • Achieve consolidated SAN tiering to meet service level requirements of tier 1 applications on FC SAN and tier 2 applications on IP SAN
  • CacheSafe technology

    Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage

    Fault-tolerant hardware modules

    Redundant controllers, PSUs, fans; high-availability hardware design, preventing "single-point-of-failure"

    Powerful management suite (SANWatch) support, including multi-pathing functions

  • Easy management and monitoring of your subsystems anywhere, locally or remotely
  • Recognize and manage redundant paths; support path failover and load-balancing
  • Multiple monitoring methods

    Real-time problem detection and notification to achieve continuous operation